Preliminary Product Listing

Model: DLVA-100M210M-70DB-50R

 

PMI Model No. DLVA-100M210M-70DB-50R is a Detector Log Video Amplifier (DLVA) that operates over the 100 MHz to 210 MHz frequency range.  This model features a dynamic range of 70 dB, ad TSS of -77 dBm typical.  Furthermore, it has been designed using cutting edge GaAs technology which provides stunning performance and reliability in a compact package making it an optimum solution for high speed channelized receiver applications.


Quick Links: (click the links below for additional information)

Product Feature

 

Specifications:

 Frequency Range  0.10 to 0.21 GHz

 Limited IF Output

(@ Full Temp. Range)

 
 Limited IF Output Level  -70 to 0 dBm
  0 dBm ±2 dB @ (140 to 180 MHz)
  0 dBm ±4 dB @ (110 to 210 MHz)
 Harmonics Level  -8 dBc Max
  110 to 210 MHz, 0 dBm
  Frequency Range Carrier to 500 MHz
 Droop Rate  5% Max
 Log Video Output
(@ Full Temp. Range)
 
 Log Range  -70 to 0 dBm
 Log Operating Frequency  160 ± 20 MHz Min
 Log In/Out Characteristic  Vo - 1450 +20 *Power In [mV] Nom
 Logging Sensitivity  ±50 mV Max ( ±2.5 dB)
 Frequency Flatness  40 mV pk-pk Max (2 dB pk-pk)
 TSS  -77 dBm Typ, -74 dBm Max
 Impedance  50 Ω Nom
 Output Coupling  DC Coupling
 Video Rise Time (10% - 90%)  25 ns Max
 Video Fall Time  70 ns Max @ (0 dBm Input, Between 90% Point and -70 dBm Point)
 Overshoot, Ringing  5% Max
 Settling Time  50 ns Max
 Input VSWR  2.0:1 Max @ (110 to 210 MHz)
 Output VSWR  2.0:1 Max @ (110 to 210 MHz)
 Power Supply  +5 V ±1% @ 35 mA Max (No Load)
  -5 V ±1% @ 125 mA Max (No Load)
 Size  1.72" x 1.11" x 0.26"
 Weight  34 g Typ, 45 g Max
 RF Connectors  Removable SMA (F)
 Finish  Nickel Plated

 

Environmental Ratings:

 Temperature  -54 ºC to +95 ºC Operating
 -65 ºC to +125 ºC Non-Operating
 Vibration  MIL-STD-202F, Method 214A
 Shock  15 g 11 ms half sin wave
  MIL-STD-202F, Method 213B
  3 Axis, 6 Directions
 Acceleration  ±10 g, MIL-STD-202F, Method 212A Cond. C
  3 Axis, 6 Directions
 Humidity  100% rh, MIL-STD-202F, Method 106E
 Altidtude  0-79000 ft,
  MIL-STD-202F, Method 105C Cond. C
 Temperature Cycle  MIL-STD-202, Method 107G
  -54 °C: 30 Minutes
  Transition Time: 15 Seconds Max
  +95 °C: 30 Minutes
  Cycling: 25 Cycles