Model: GMTA-1002-1

PMI Model No. GMTA-1002-1 is a 2.0 to 18.0GHz Threshold Detector with an input operating range of -18 to -23dBm and a maximum input VSWR of 2.5:1.  this unit has a minimum threshold level of -23dBm and a threshold setting stability of ±3.0dB over temperature and frequency. it is supplied with SMA(F) connectors in a housing measuring 1.0" x 0.65" x 0.3".


Quick Links: (click the links below for additional information)

Product Feature

Test Report

 

Specifications:

Frequency Range 2.0 to 18.0GHz
Input Operating Range -18 to -23dBm
Input VSWR 2.5:1 max
Threshold Level -23dBm min
Threshold Setting Stability ±3.0dBm (Over Temp and Frequency)
Maximum Input Power +10dBm (Without Damage)

Detected Output

TTL High (1) - On
TTL Low (0) - Off
Response Time Any Input Greater than 3dB
100us @ 90% RF to TTL (1)
100us @ 10% RF to TTL (0)
DC Supply +12VDC @ 50mA
Weght 2oz max
Size 1.0" x 0.65" x 0.3"
Finish Nickel Plated

Environmental Ratings:

Temperature:  -20ºC to +85ºC Operating
 -62ºC to +85ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A