Model: TD-218-RB 

 

PMI Model Number TD-218-RB is a Threshold Detector optimized for the 2 to 18GHz  frequency range.  It has an internally fixed threshold level providing a minimum signal level of -30dBm and a maximum input VSWR of 2.75:1.  The threshold setting stability is constant ± 3.0 dB over the operating temperature and frequency.

Quick Links: (click the links below for additional information)

Product Feature

Test Data

Test Report

3-D STEP File (Right Click on link and "Save Target As" to download the 3-D STEP Model)

PL20168

PL20176

PL20180

PL20190

PL20192

 

Specifications:

Frequency Range 2 GHz to 18 GHz
Input Operating Range -32 dBm to -10 dBm (2-18 GHz)
Input VSWR 2.75:1 (2-18 GHz) - Measured 1.6:1
Threshold Level Internally fixed to provide a minimum signal level of -30 ± 1.5 dBm at 6 GHz
Threshold Setting Stability ± 3.0 dB over the operating temperature and frequency range - Measured 1.3 dB
Maximum Power Input +10 dBm (without damage)
Detected Output The detected output signal shall be a TTL level high when the RF signal applied to the RF input exceeds the threshold level.  Any signals below the threshold level shall result in an output level of TTL low (0).  The TTL output shall be buffered in such that output loading has no effect on detector response.  The detected output shall have a drive capacity of at least two standard TTL loads.
Response Time For any RF input greater than 3 dB above threshold, the maximum turn on response time measured at 90% RF to a TTL "1" output shall be 100 nS.  The maximum turn off response time measured at 10% RF to a TTL "0" shall be 100 nS. - Measured 71 ns
Connectors The input signal connector shall be an SMA female in accordance with MIL-C-39012.  The output signal connection shall be a solderable pin (ø 0.023" Minimum) with a ground lug next to it.  The power connection shall be a solderable pin (ø 0.023" Minimum).
Power Supply Voltage

+15V @ 250 mA Maximum

Measured 132 mA

Size 1.50" (L) x 1.50" (W) x 0.50" (H)
Weight 2.0 Ounces

Environmental Ratings:

Temperature:  -55ºC to +85 ºC Operating
 -65 ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A