Model: 12SFB8D1G-15D8G-CD-SFF

Model 12SFB8D1G-15D8G-CD-SFF is a a twelve channel switch filter bank. This model has twelve filter channels that cover the frequency range of 0.2GHz to 16.0GHz. This model includes an integral TTL driver and offers fast switching speeds of less than 100nsec.


Quick Links: (click the links below for additional information)

Product Feature

 

Specifications:

Number of Filter Channels 12 Channels
Channel 1 Specifications:  
Channel 1Passband 167 to 233MHz
Channel 1 Rejection

5 Pole Response

Channel 2 Specifications:  
Channel 2 Passband 167 to 233MHz
Channel 2 Rejection

5 Pole Response

Channel 3 Specifications:  
Channel 3 Passband 417.5 to 582.5MHz
Channel 3 Rejection

5 Pole Response

Channel 4 Specifications:  
Channel 4 Passband 417.5 to 582.5MHz
Channel 4 Rejection

5 Pole Response

Channel 5 Specifications:  
Channel 5 Passband 668 to 932MHz
Channel 5 Rejection

5 Pole Response

Channel 6 Specifications:  
Channel 6 Passband 668 to 932MHz
Channel 6 Rejection

5 Pole Response

Channel 7 Specifications:  
Channel 7 Passband 3340 to 4660MHz
Channel 7 Rejection

5 Pole Response

Channel 8 Specifications:  
Channel 8Passband 3340 to 4660MHz
Channel 8 Rejection

5 Pole Response

Channel 9 Specifications:  
Channel 9 Passband 8350 to 11,650MHz
Channel 9 Rejection

5 Pole Response

Channel 10 Specifications:  
Channel 10 Passband 8350 to 11,650MHz
Channel 10 Rejection

5 Pole Response

Channel 11 Specifications:  
Channel 11 Passband 13,400 to 18,600MHz
Channel 11 Rejection

5 Pole Response

Channel 12 Specifications:  
Channel 12 Passband 13,400 to 18,600MHz
Channel 12 Rejection

5 Pole Response

Common Specifications:  
Insertion Loss 5.0dB max.
Isolation: 60dB min.
VSWR 2.0:1 max.
Switching Speed 100nsec max.
Control

4 Line TTL Decoded

RF Power Rating +30dBm CW max.
Power Supply

330mA @ +5VDC max.

30mA @ -5VDC max.

Connectors SMA(F)
Size 7.0"L x 3.0"W x 0.75"H

Environmental Ratings:

Temperature:  -40ºC to +85 ºC Operating
 -40 ºC to +100 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A