Model: 8SFB-6G18G-CD-15-SFF-HSS  

PMI Model No. 8SFB-6G18G-CD-15-SFF-HSS is a an eight channel switch filter bank. This model has eight filter channels within the 6.0 to 18.0GHz frequency range.  This model includes an integral TTL driver and offers fast switching speeds of less than 100nsec.


Quick Links: (click the links below for additional information)

Product Feature

Test Data

 

Specifications:

Number of Filter Channels 8 Channels
Channel 1 Specifications:  
Channel 1Center Frequency 7.0GHz
Channel 1 -3dB Bandwidth 2.0GHz
Cannel 1 Rejection

-35dBc min. @ 167% BW

Channel 2 Specifications:  
Channel 2 Center Frequency 8.5GHz
Channel 2 -3dB Bandwidth 1.0GHz
Channel 2 Rejection

-35dBc min. @ 167% BW

Channel 3 Specifications:  
Channel 3 Center Frequency 9.25GHz
Channel 3 -3dB Bandwidth 0.5GHz
Channel 3 Rejection

-35dBc min. @ 167% BW

Channel 4 Specifications:  
Channel 4 Center Frequency 9.75GHz
Channel 4 -3dB Bandwidth 0.5GHz
Channel 4 Rejection

-35dBc min. @ 167% BW

Channel 5 Specifications:  
Channel 5 Center Frequency 11.0GHz
Channel 5 -3dB Bandwidth 2.0GHz
Channel 5 Rejection

-35dBc min. @ 167% BW

Channel 6 Specifications:  
Channel 6 Center Frequency 13.0GHz
Channel 6 -3dB Bandwidth 2.0GHz
Channel 6 Rejection

-35dBc min. @ 167% BW

Channel 7 Specifications:  
Channel 7 Center Frequency 14.5GHz
Channel 7 -3dB Bandwidth 1.0GHz
Channel 7 Rejection

-35dBc min. @ 167% BW

Channel 8 Specifications:  
Channel 8 Center Frequency 16.5GHz
Channel 8 -3dB Bandwidth 3.0GHz
Channel 8 Rejection

-35dBc min. @ 167% BW

Common Specifications:  
Insertion Loss

5.5dB Filter Channels 1 thru 7

7.5dB Filter Channel 8

VSWR 2.0:1 max.
Switching Speed 100nsec max. / 50nsec typical
Control

3 Line Decoded TTL

Power Supply

200mA @ +15VDC max.

200mA @ -15VDC max.

Connectors SMA(F)
Size 4.33"L x 5.1"W x 0.98"H

Environmental Ratings:

Temperature:  -40ºC to +85 ºC Operating
 -65ºC to +125 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A