Model: SFB-13-6P-MCT

Model SFB-13-6P-MCT is a a six channel switch filter bank. This model has six filter channels that cover the frequency range of 1.38GHz to 2.62GHz. This model includes an integral TTL driver and offers fast switching speeds of less than 500nsec.


Quick Links: (click the links below for additional information)

Product Feature

 

Specifications:

Number of Filter Channels 6 Channels
Channel 1 Specifications:  
Channel 1Center Frequency 1.48GHz
Channel 1 -0.5dB Bandwidth 240MHz
Cannel 1 Rejection

-60dB min. @ 1200MHz and 1800MHz

-65dB min. @ DC to 1000MHz

-65dB min. @ 2100 to 6000MHz

Channel 2 Specifications:  
Channel 2 Center Frequency 1.7GHz
Channel 2 -0.5dB Bandwidth 240MHz
Channel 2 Rejection

-60dB min. @ 1400MHz and 2000MHz

-65dB min. @ DC to 1100MHz

-65dB min. @ 2300 to 6000MHz

Channel 3 Specifications:  
Channel 3 Center Frequency 1.9GHz
Channel 3 -0.5dB Bandwidth 240MHz
Channel 3 Rejection

-60dB min. @ 1600MHz and 2200MHz

-65dB min. @ DC to 1300MHz

-65dB min. @ 2500 to 6000MHz

Channel 4 Specifications:  
Channel 4 Center Frequency 2.1GHz
Channel 4 -0.5dB Bandwidth 240MHz
Channel 4 Rejection

-60dB min. @ 1800MHz and 2400MHz

-65dB min. @ DC to 1500MHz

-65dB min. @ 2700 to 6000MHz

Channel 5 Specifications:  
Channel 5 Center Frequency 2.3GHz
Channel 5 -0.5dB Bandwidth 240MHz
Channel 4 Rejection

-60dB min. @ 2000MHz and 2600MHz

-65dB min. @ DC to 1700MHz

-65dB min. @ 2900 to 6000MHz

Channel 6 Specifications:  
Channel 6 Center Frequency 2.5GHz
Channel 6 -0.5dB Bandwidth 240MHz
Channel 6 Rejection

-60dB min. @ 2200MHz and 2800MHz

-65dB min. @ DC to 1900MHz

-65dB min. @ 3100 to 6000MHz

Common Specifications:  
Insertion Loss 3.8dB max.
Isolation: 60dB min.
VSWR 2.0:1 max.
Switching Speed 500nsec max.
Control

6 Line TTL

RF Power Rating +27dBm CW max.
Power Supply

700mA @ +15VDC max.

50mA @ -15VDC max.

Connectors SMA(F)
Size 5.0"L x 4.0"W x 1.5"H

Environmental Ratings:

Temperature:  -40ºC to +85 ºC Operating
 -40 ºC to +100 ºC Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A