Model: SFB-218-SP6DR-HPM

Model SFB-218-SP6DR-HPM is a six channel switch filter bank. This model has six filter channels that cover the frequency range of 2.0 GHz to 18.5 GHz. This model includes an integral TTL driver and offers fast switching speeds of less than 1 µs.


Quick Links: (click the links below for additional information)

Product Feature

Test Report

3D Model - STEP File

 

Specifications:

Number of Filter Channels 6 Channels
Channel 1 Specifications:  
Channel 1 Center Frequency 2.5 GHz
Channel 1 -3 dB Bandwidth 1 GHz
Cannel 1 Rejection

-40 dB Min @ 300 kHz to 1.6 GHz

-40 dB Min @ 9.1 to 18.5 GHz

-60 dB Min @ 3.98 to 9.1 GHz

Channel 2 Specifications:  
Channel 2 Center Frequency 4.0 GHz
Channel 2 -3 dB Bandwidth 2.0 GHz
Channel 2 Rejection

-40 dB Min @ 300 kHz to 2.6 GHz

-40 dB Min @ 15.1 to 18.5 GHz

-60 dB Min @ 5.9 to 16.1 GHz

Channel 3 Specifications:  
Channel 3 Center Frequency 6.5 GHz
Channel 3 -3 dB Bandwidth 3.0 GHz
Channel 3 Rejection

-40 dB Min @ 300 kHz to 4.1 GHz

-60 dB Min @ 9.9 to 18.5 GHz

Channel 4 Specifications:  
Channel 4 Center Frequency 9.5 GHz
Channel 4 -3 dB Bandwidth 3.0 GHz
Channel 4 Rejection

-40 dB Min @ 300 kHz to 5.6 GHz

-60 dB Min @ 15.9 to 18.5 GHz

Channel 5 Specifications:  
Channel 5 Center Frequency 12.5 GHz
Channel 5 -3 dB Bandwidth 3.0 GHz
Channel 5 Rejection

-40 dB Min @ 300 kHz to 7.1 GHz

Channel 6 Specifications:  
Channel 6 Center Frequency 16.25 GHz
Channel 6 -3 dB Bandwidth 4.5 GHz
Channel 6 Rejection

-40 dB Min @ 300 kHz to 9.4 GHz

Common Specifications:  
Insertion Loss 6.0 dB Max
Isolation 60 dB Min
VSWR 2.0:1 Max
Switching Speed 1 µs Max
Control

3 Line TTL Decoded

RF Power Rating +33 dBm CW Max
Power Supply

250 mA @ +15 VDC Max

150 mA @ -15 VDC Max

Connectors SMA Female
Size 4.0" (L) x 3.5" (W) x 1.2" (H)

Environmental Ratings:

Temperature -40 ºC to +85 ºC Operating
-40 ºC to +100 ºC Non-Operating
Humidity MIL-STD-202, Method 103B Cond. B
Shock MIL-STD-202, Method 213B Cond. B
Vibration MIL-STD-202, Method 204D Cond. B
Altitude MIL-STD-202, Method 105C Cond. B
Temperature Cycle MIL-STD-202, Method 107D Cond. A