Model No. PIA-BTFL-GPO-2CH (Revision B)

        

PMI model number PIA-BTFL-GPO-2CH Revision B is an dual channel integrated assembly that consists of a Bias-Tee,  High Pass Filter, and Limiter. This compact module is supplied with field replaceable GPO connectors.  The module is hermetically sealed..

Quick Links: (click the links below for additional information)

Product Feature

Test Report

MTBF Analysis

Environmental Testing Report

Unit Data

  PL11278 PL11283
  PL11279 PL11284
  PL11280 PL11285
  PL11281 PL11286
  PL11282 PL11287

Specifications:

Passband Lower Limit 2.0 GHz Typ
Passband Upper Limit 19.0 GHz
-3 dB Cut-Off 1.8 GHz Typical (3 dBc from Insertion Loss measured at 2 GHz)
Insertion Loss 3.0 dB Typ, 3.5 dB Max (2.0 to 19.0 GHz)
Filter Rejection

-10 dBc Min @ 1.7 GHz

-30 dBc Min @ DC to 1.5 GHz

(Referenced to measured Insertion Loss at 2 GHz)

Passband VSWR

2.0:1 Max (3.0 to 19.0 GHz)

2.2:1 Max (2.0 to 3.0 GHz)

Bias Rise / Fall Time

50 ns Max (90% to 10%) +12 to -12 V or -12 to +12 V pulses,
tr = 1 ns; Rload = 430 Ohms

Limiting Threshold

+8 dBm Min

Flat Leakage

+20 dBm CW Max

+23 dBm Pulsed Max

Pulse Recovery Time 50 ns Max (To within 1 dB of Insertion Loss)
Cross Channel Isolation -73 dB Min
2nd Order Input Intercept Point +30 dB Min (-15 dBm Tones)
3rd Order Input Intercept Point +17dB Min (-15 dBm Tones)
Power Handling

1 W CW Max

20 W ( 20% Duty Cycle)

Bias Current ±30 mA Operational (±80 mA Max)
Bias Voltage -12 to +12 VDC
Connectors GPO - Full Detent
Size 1.5" (L) x 1.5" (W) x 0.4" (H)
Finish

MIL-SPEC Epoxy Paint (Gray Color)

Mounting Surface to be paint free.

Sealing Hermetic
Weight 3 ounces Typ

 

Environmental:

Temperature: -27 ºC to +95 ºC Operating (+25ºC - Specificatons)
-65 ºC to +125 ºC Non-Operating
Humidity MIL-STD-202F, Method 103B, Condition B
Shock

MIL-STD-202F, Method 213B, Condition B

Vibration MIL-STD-202F, Method 204C, Condition B
Temperature Cycle MIL-STD-202F, Method 107
Salt Fog MIL-STD-202F, Method 101D-EST, Condition B
Thermal Shock MIL-STD-202F, Method 107C, Condition A

 

.