Integrated Bias-Tee, Filtered Limiter Module     

Model No. PIA-BTFL-GPO-2CH (Revision B)

        

PMI model number PIA-BTFL-GPO-2CH Revision B is an dual channel integrated assembly that consists of a Bias-Tee,  High Pass Filter, and Limiter. This compact module is supplied with field replaceable GPO connectors.  The module is hermetically sealed..

Quick Links: (click the links below for additional information)

Product Feature

Test Report

MTBF Analysis

Environmental Testing Report

 

Specifications:

Passband Lower Limit 2.0GHz Typical
Passband Upper Limit 19.0GHz
-3dB Cut-Off 1.8GHz Typical (3dBc from Insertion Loss measured at 2GHz)
Insertion Loss 3.0dB Typical, 3.5dB Max. (2.0 to 19.0GHz)
Filter Rejection

-10dBc Min. @ 1.7GHz

-30dBc Min @ DC to 1.5GHz

(Referenced to measured Insertion Loss at 2GHz)

Passband VSWR

2.0:1 Max. (3.0 to 19.0GHz)

2.2:1 Max. (2.0 to 3.0GHz)

Bias Rise / Fall Time

50nsec Max. (90% to 10%) +12 to -12V or -12 to +12V pulses, tr=1nsec; Rload = 430 Ohms

Limiting Threshold

+8dBm Min.

Flat Leakage

+20dBm CW Max.

+23dBm Pulsed Max.

Pulse Recovery Time 50nsec Max. (To within 1dB of Insertion Loss)
Cross Channel Isolation -73dB Minimum
2nd Order Input Intercept Point +30dB Min. (-15dBm Tones)
3rd Order Input Intercept Point +17dB Min. (-15dBm Tones)
Power Handling

1W CW Max.

20W ( 20% Duty Cycle)

Bias Current ±30mA Operational (±80mA Max)
Bias Voltage -12 to +12VDC
Connectors GPO - Full Detent
Size 1.5" (L) x 1.5" (W) x 0.4" (H)
Finish

MIL-SPEC Epoxy Paint (Gray Color)

Mounting Surface to be paint free.

Sealing Hermetic
Weight 3 ounces Typical

 

Environmental:

Temperature: -27ºC to +95 ºC Operating (+25ºC - Specificatons)
-65 ºC to +125 ºC Non-Operating
Humidity MIL-STD-202F, Method 103B, Condition B
Shock

MIL-STD-202F, Method 213B, Condition B

Vibration MIL-STD-202F, Method 204C, Condition B
Temperature Cycle MIL-STD-202F, Method 107
Salt Fog MIL-STD-202F, Method 101D-EST, Condition B
Thermal Shock MIL-STD-202F, Method 107C, Condition A

 

.