General Parameters: |
Type: | DLVA |
Status: | Active |
Frequency Range: | 2 to 18 GHz |
Frequency Min: | 2 GHz |
Frequency Max: | 18 GHz |
TSS: | -65 dBm Max |
TSS (Measured): | -65 dBm Max - Measured -66 dBm |
Size: | 3.5" x 3.2" x 0.5" |
Output Voltage: | +2.5 V Max |
Log Slope: | +25 ± 1 mV/dB at Room Temperature - Measured 24.9 mV/dB +25 ± 2 mV/dB over Room Temperature - Measured 24.7 mV/dB +25 mV/dB typ |
Log Range: | -60 to +7 dBm |
Log Linearity: | ±1.5 dB Max at Room Temperature - Measured +0.87 dB / -0.53 dB ±2.0 dB Max over Room Temperature - Measured +1.42 dB / -0.62 dB |
Rise Time: | 30 ns Max |
Recovery Time: | 1 µs Max - Measured 0.50 µs |
Power Supply: | +12 to +15 VDC @ 400 mA Max, -12 to -15.5 VDC @ 165 mA Max |
Finish: | Electroless Nickel Plate |
VSWR: | 2.3:1 Max - Measured 1.86:1 |
Video Load Impedance: | 75 Ohm |
Flatness: | 100 mV Max - Measured 42 mV |
RF Safe Input Power: | +23 dBm Max CW |
Throughput Time: | 30 ns Max |
Video Bandwidth: | 10 MHz Typ |
Offset Voltage: | ±50 mV Max - Measured -8 mV |
Environmental Ratings: |
Operating Temperature: | -54 ºC to +85 ºC |
Non-Operating Temperature: | -57 ºC to +85 ºC |
Temperature Cycle: | MIL-STD-202F, Method 107D Cond A Functional Shock: 196 m/s, 6(squared)~9ms |
Humidity: | MIL-HDBK-5400 4.6.2.4 100% RH |
Shock: | MIL-HDBK-5400 4.6.2.6 |
Vibration: | MIL-STD-810F ANNEX C, FIG. 514.5C-8 (Refer to Fig.1) |
Altitude: | 0 ~ 43,000 FT |